Prescription
Hematocrit & pre-pump fluids
Effluent dose
Filtration fraction
Equations and assumptions
Effluent = QD + Qpre + Qpost + net UF + pre-pump infusion
Pre-dilution factor = QB ÷ (QB + Qpre + pre-pump infusion)
Delivered dose = effluent ÷ weight × pre-dilution factor × hours running ÷ 24
Filtration fraction = (Qpre + Qpost + net UF + pre-pump) ÷ (plasma flow + Qpre + pre-pump), plasma flow = QB × (1 − Hct)
- KDIGO (2012) suggests delivering an effluent volume of 20–25 mL/kg/h for CRRT in AKI; because of downtime and pre-dilution this usually means prescribing more.
- The pre-dilution correction uses blood flow, as in common practice; using plasma flow gives a slightly lower factor.
- Dialysate is diffusive and does not count toward filtration fraction. A filtration fraction above about 20–25% raises the risk of filter clotting.
- Small-solute clearance falls below effluent rate when dialysate is not fully saturated (high QD relative to QB) or the filter is clotting.
Clinical disclaimer — read before using
DISCLAIMER: The authors make no claim of the accuracy of the information contained herein. The calculations suggested above are inherently prone to errors and bias, and should not be a substitute for clinical judgement. The authors involved in the preparation of the site and its content should not be liable for any special, consequential, or exemplary damages resulting in whole or part from any user's use of or reliance upon this material. PLEASE READ THE DISCLAIMER PRIOR TO USING THE SITE. BY ACCESSING AND USING THIS SITE, YOU AGREE TO BE BOUND BY THE TERMS AND CONDITIONS OF THE DISCLAIMER.